TM 9-6115-661-13&P
REMOVAL
1. Drill out rivets (1, figure 4-12) that secure clamping catch (2).
2. Remove defective clamping catch(2).
INSTALLATION
1. Position new clamping catch (2) and secure with rivets (1).
2. Close cover.
c. Installation
This task covers: a. Removal
b. Test
INITIAL SETUP
Equipment Conditions
Tools
Reference
Tool Kit, General Mechanic's
(item 1, appendix B)
Both generator sets shut down,
Multimeter, AN/PSM-45
paragraph 2-5.3.1.
(item 2, appendix B)
Trailer support devices are
lowered, paragraph 2-3.2.1.
Figure 4-13. Switch Replacement
|