TM 9-6115-661-13&P
REMOVAL
1. Release clamping catch (5, Figure 4-13) and open the control panel access cover (1).
2. Remove 8 screws (4), flat washers (2) and lock washers (3). Remove control panel assembly (10).
3. Tag wires on terminals 3, 4 and 6 of switch (12).
4. Remove terminal screws (16), lock washers (15), flat washers (14) and conductor bus (13) from switch
terminals.
5. Remove nut (7), lock washer (8), locking ring (9) and switch (12).
TEST
1. Set multimeter for continuity test.
2. With switch (12) in center position, check continuity of switch between terminals 3 and 5.
3. If no continuity in step 2, replace switch.
4. With switch (12) in OFF position, check continuity of switch between:
a.
Terminals 3 and 5
b.
Terminals 2 and 6
c.
Terminals 3 and 6
d.
If there is continuity in step a, b, or c, replace switch.
INSTALLATION
1. Remove nut (7), lock washer (8), and locking ring (9) from new switch.
2. Hand tighten nut (11) on switch.
NOTE
Make sure terminals 3 and 6 of switch are toward bottom of panel when
installing switch.
3. Insert switch body (12) into mounting hole and position nut (11) against control panel assembly (10).
4. Install locking ring (9) into keyway of switch until alignment tip goes into control panel assembly
(10).
5. Install lock washer (8) against locking ring (9).
6. Install nut (7) and tighten, making sure that locking ring (9) alignment tip is engaged in control
panel assembly (10).
7. Remove screws (16) with washers from terminals of new switch (12).
|