TM 9-6115-663-13&P
REMOVAL
1. Drill out rivets (1, figure 4-11) that secure clamping catch (2).
2. Remove defective clamping catch (2).
INSTALLATION
1. Position new clamping catch (2) and secure with rivets (1).
2. Close cover.
This task covers: a. Removal
c. Installation
b. Test
INITIAL SETUP
Tools
Equipment Conditions
Tool Kit, General Mechanic's
Reference
(item 1, appendix B)
Both generator sets shut down,
Multimeter, AN/PSM-45
paragraph 2-5.3.1.
(item 2, appendix B)
Trailer support devices are
lowered, paragraph 2-3.2.1.
|