TM 9-6115-661-13&P
INSTALLATION
1. Position bus bar (1, figure 5-14) in place.
2. Install flatwashers (8), newlock washers (7) and nut (6).
3. Install lock washers (2) and nut (3).
4. Install leads (5), flat washers (9), lock washers (10) and cap screws (4).
5. Connect P3 (7) to J4 (8, figure 5-13) and position the switch box cover (4) over the switch box
assembly.
6. Install flat washers (3), lock washers (2), and screws (1) that secure the switch box cover (4).
b. Installation
This task covers: a. Removal
INITIAL SETUP
Tools
Equipment Conditions
General Mechanic's Tool Kit
Reference
(item 1, appendix B)
Both generator sets shut down,
Materials/Parts
para 2-5.3.1.
Washer, Lock
REMOVAL
1. Remove 21 screws (1, figure 5-15), lock washers (2), flat washers (3) that secure the switch box cover
(4) to the switch box assembly. Discard lock washers.
CAUTION
The control panel connector P3 is connected to connector J4. Movement
of the switch box cover is limited. To prevent damage to control panel
wiring harness, use caution removing switch box cover. Failure to
observe this caution can result in equipment damage.
2. Carefully position switch box cover (4) in front of the switch box assembly.
3. Disconnect P3 (5) from J4 (6) and set switch box cover (4) out of the way.
4. Remove and retain the switch box cover (4).
5. Remove four screws (7, figure 5-15) and one terminal shield (8) from the contactor (9).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |