2. Remove 8 screws (9), flat washers (11), and lock washers (10) that secure control panel assembly
(12). Discard lock washers.
3. Disconnect P3 (7) from J4 (8).
4. Remove the control panel assembly (12).
REPAIR
NOTE
Spare lamps must be tied to ground for electromagnetic interference (EMI) protection.
Refer to appendix G and repair or manufacture wiring harness W20.
INSTALLATION
1. Connect P3 (7) to J4 (8).
2. Position new control panel assembly on mounting plate and align mounting holes.
3. Install new lock washers (10), flat washers (11), and screws (9) that secure control panel assembly
(12) to switch box assembly (4).
4. Close the control panel access cover (5) and secure with clamping catch (6).
This task covers: a. Removal
c. Installation
d. Inspection
b . Repair
INITIAL SETUP
Equipment Conditions
Tools
Reference
General Mechanic's Tool Kit
(item 1, appendix B)
Both generator sets shut down,
Materials/Parts
para 2-5.3.1.
Washers, Lock
REMOVAL
1. Remove 21 machine screws (1, figure 5-13), lock washers (2), and flat washers (3) that secure the
switch box access cover (4) to the switch box assembly. Discard lock washers.
|