|
|
TM 9-6115-661-13&P
Section VII. ADMINISTRATIVE STORAGE
4-31.1 Short Term Storage. This type of storage is used when the equipment is expected to be stored
from 1 to 45 days. The storage maybe at destination after domestic shipment, or maybe administrative
storage when there is a shortage of maintenance manpower. For administrative storage:
a. Perform current maintenance services and serviceability criteria evaluations before placing
equipment in administrative storage. Correct shortcomings and deficiencies and check that all
modification work orders have been applied.
b, If possible, select an inside storage site. If inside storage is not available, a truck, van, conex
container, or other container may be used.
c. When in administrative storage, the equipment should be capable of being made mission ready
within 24 hours unless a different time frame is directed by the approving authority.
4-31.2 Intermediate Term Storage. This type of storage is used when the equipment is expected to be
stored from 45 to 180 days. Level A or B preservation and packing may be required.
4-31.3 Long Term Storage. This type of storage is used when the equipment is expected to be stored
for more than 180 days. Level A preservation and packing maybe required.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |