TM 9-2320-361-24-1
FIELD MAINTENANCE INSTRUCTIONS
2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL)
AIR CLEANER INDICATOR AND TUBE MAINTENANCE
TESTING, REMOVAL, INSPECTION AND CLEANING, AND INSTALLATION
INITIAL SETUP:
Applicable Models
Personnel Required
Two
All
Equipment Condition
Materials/Parts
Parking brake set and wheels chocked
Antiseize tape (item 42, WP 0468 00)
(TM 9-2320-361-10).
Hood raised and secured (TM 9-2320-361-10).
TESTING
1.
Loosen clamp (6) and remove cap (7) and clamp (6) from air cleaner (5).
2.
Start engine (TM 9-2320-361-10) and run at 1200 rpm.
3.
Using cardboard (4), cover approximately 90% of air cleaner assembly (5) opening.
4.
Observe air cleaner indicator (2) to see if red band (3) is visible.
a. If red band (3) is visible, indicator (2) works properly.
b. If red band (3) is not visible, refer to Inspection and Cleaning in this WP.
5.
Stop engine (TM 9-2320-361-10).
6.
Remove cardboard (4) and install cap (7) on air cleaner (5) with clamp (6).
4
5
1
3
6
2
7
0054 00-1