TM 9-2320-361-24-1
0054 00
AIR CLEANER INDICATOR AND TUBE MAINTENANCE (Contd)
REMOVAL
1.
Disconnect tube (6) from connector (7) and remove connector (7) from air cleaner head (8).
NOTE
Step 2 must be performed with two personnel.
2.
Remove two nuts (4), screws (1), and clamps (3) from tube (6) on firewall (5).
3.
Remove two nuts (9), screws (13), and washers (12) from air cleaner indicator (11).
4.
Disconnect tube (6) from adapter (10) and remove air cleaner indicator (11).
5.
Remove adapter (10) from air cleaner indicator (11).
6.
Remove tube (6) and grommet (2) from firewall (5),
INSPECTION AND CLEANING
1.
Inspect tube (6) for kinks and obstruction. Replace tube (6) if kinked or obstructed.
WARNING
Compressed air source must not exceed 30 psi (207 kPa). Wear
eyeshields when cleaning with compressed air. Failure to wear
eyeshields may result in injury to personnel.
2.
Clean tube (6) by blowing through it with compressed air.
3.
Inspect connector (7), adapter (10), and fittings on tube (6) for stripped threads. Replace
connector (7), adapter (10), or fittings on tube (6) if threads are stripped.
INSTALLATION
NOTE
Male pipe threads must be wrapped with antiseize tape before
installation.
1.
Install grommet (2) and tube (6) into firewall (5).
2.
Install adapter (10) on air cleaner indicator (11).
3.
Connect air cleaner indicator (11) to tube (6).
4.
Install two screws (13), washers (12), and nuts (9).
NOTE
Step 5 must be performed with two personnel.
5.
Install tube (6) on firewall (5) with two clamps (3), screws (1), and nuts (4). Do not tighten
nuts (4).
6.
Install connector (7) on air cleaner head (8), and connect tube (6) to adapter (7). Tighten nuts (4).
7.
Lower and secure hood (TM 9-2320-361-10).
8.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).
0054 00-2
|