Click here to make tpub.com your Home Page

Page Title: Figure 2-8. RAINSHIELD assembly application.
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 3-6665-225-12
(19) below.
flowmeter ball (6) is in the blue zone (8), proceed to
(19) Press in hand crank (2, fig. 2-1) and release
(19) below. If flowmeter ball (6) indicates no airflow,
it.
proceed to (17) below. If flowmeter ball (6) indicates
NOTE
low airflow, proceed to (18) below.
Keep hand crank in the down position, not
NOTE
pressed in.
Adjust HORN VOL-BATTERY TEST knob
(20) After 10 minutes of operation at normal
(6, fig. 2-1) for low volume. Position M42
airflow, press and rotate ZERO ADJUST knob (5)
alarm unit selector switch (8, fig. 1-5) to
until meter (1) indicates in ZERO ADJUST zone
HORN OFF or disconnect one wire from
(blue). Repeat at 10-minute intervals until meter
M43 detector unit REMOTE binding post
reading is stable.
(21) Disconnect power source from the 24 VDC
(17) If no airflow is indicated, press ZERO
INPUT connector (11, fig. 1-2) of M43 detector unit.
ADJUST knob (5, fig. 2-1), rotate it fully clockwise,
Position M42 alarm unit selector switch (8, fig. 1-5)
and release it. Horn must sound. Check airflow
to HORN ON or reconnect wire to M43 detector
every 2 minutes by pressing ZERO ADJUST knob
unit REMOTE binding post (17, fig. 1-2).
(5) and observing FLOWMETER (2, fig. 2-6). When
(22) Remove protective cap from the sensitivity
bail (6) rises in FLOWMETER, indicating low air-
check bottle (6, fig. 1-6). Unscrew AIR FILTER plug
flow, press ZERO ADJUST knob (5, fig. 2-1) and
(4, fig. 2-4) and remove air filter (3).
rotate it fully counterclockwise and proceed to (18)
(23) Invert sensitivity check bottle and, while
below.
holding dropper tip 1/2 inch over center of black
(18) If low airflow is indicated, let pump as-
side of filter material (2), allow two drops of
sembly operate until correct airflow (blue zone) is
indicated (less than 30 minutes). Then proceed to
Figure 2-8. RAINSHIELD assembly application.
horn (3) must sound, M42 alarm unit loudspeaker
solution to fall on the filter.
(5, fig. 1-5) must sound, and ALARM-RED indicator
(24) Immediately replace air filter (3) in M43
(3) must flash.
detector unit and secure AIR FILTER plug (4). Re-
NOTE
place cap on sensitivity check bottle.
If M43 detector unit horn sounds in less
(25) Connect power source to 24 VDC INPUT
than 15 seconds, disconnect power source
connector (11, fig. 1-2) of M43 detector unit.
and return unit to organizational mainte-
(26) Immediately press and hold ZERO AD-
nance through your supervisor.
JUST knob (5, fig. 2-1) for 5 seconds and release it.
Within 15 seconds to 5 minutes, M43 detector unit
Change 2
2-13

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business