4. With switch (12) in OFF position, check continuity of switch between:
a. Terminals 3 and 5
b. Terminals 2 and 6
c. Terminals 3 and 6
d. If there is continuity in step a, b, or c, replace switch.
INSTALLATION
1.
Remove nut (7), lock washer (8), and locking ring (9) from new switch.
2.
Hand tighten nut (11) on switch.
NOTE
Make sure terminals 3 and 6 of switch are toward bottom of panel when
installing switch.
Insert switch body (12) into mounting hole and position nut (11) against control panel assembly (10).
3.
4.
Install locking ring (9) into keyway of switch until alignment tip goes into control panel assembly
(10).
Install lock washer (8) against locking ring (9).
5.
6.
Install nut (7) and tighten, making sure that locking ring (9) alignment tip is engaged in control
panel assembly (10).
7.
Remove screws (16) with washers from terminals of new switch (12).
Install conductor bus (13) between terminals 2 and 5.
8.
9.
Install tagged wires, screws (16), and washers (14 and 15) to terminals.
10. Position control panel assembly (10) with gasket (17) on switch box cover (6) and align mounting
holes.
11. Install 8 new lock washers (3), flat washers (2), and screws (4).
12. Close switch box cover (1) and secure with clamping catch (5).