3. Refer to power plant wiring diagram (figure FO-1)for identification of components inside stitch box
assembly and check:
a. Refer to table 5-1 and Check continuity of wiring harness W20 (7).
From
To
Wire Number
P3-A
1
XDS1-1
P3-B
2
XDS1-2
P3-C
3
XDS3-2
4
P3-D
S1-3
P3-F
5
S1-5
P3-G
6
S1-6
P3-H
7
S2-6
P3-I
8
S2-5
P3-K
9
S2-3
P3-L
10
XDS4-2
11
XDS2-1
P3-M
12
XDS2-2
P3-N
XDS3-1
13
S1-3
14
XDS4-1
S2-3
b. Remove electrical connector cover, refer to table 5-2 and check continuity of wiring harness W9 (18).
NOTE
The bus bar is physically connected to LO of the switch box assembly and
is a common ground. Wires connected to bus bar may be connected to
any terminal on the bus bar.
|