WARNING
Ensure nut (3) is properly secured creating a good ground. Failure to observe this
warning could result in severe personal injury or death
Install flat washer (4), hex nut (3), two flat washers (2), and wing nut (1).
(3)
(4)
Route ground wire (6) thru power cable sock (7).
(5)
Connect ground wire (6) to generator set ground terminal (8).
4-5.2.3 ASSEMBLY OF POWER UNIT PU-801.
Refer to figure 4-2A and assemble as follows.
a. Remove 48 inch ground wire from accessory box and connect as follows.
(1)
Remove wing nut (1, figure 4-2A). two flat washers (2), hex nut (3), and flat washer (4) from ground stud
(5).
Ensure hex nut (3) is properly secured creating a good ground. Failure to observe this
warning could result in severe personal injury or death.
(2)
Install fiat washer (4), hex nut (3), two flat washers (2), and wing nut(1).
Route ground wire (6) thru power cable sock (7).
(3)
(4)
Connect ground wire (6) to generator set ground terminal (8).
4-6 PRELIMINARY SERVICING AND ADJUSTMENT OF EQUIPMENT.
Refer to TM 9-6115-643-24 for generator set and TM 9-2815-254-24 for engine. Refer to TM 9-2330-205-
14&P for 2 1/2 ton trailer, TM 9-2330-202-14&P for 1 ton trailer, and TM 9-2330-392-14&P for high