TM 9-2320-391-10
SPECIAL PURPOSE KITS TROUBLESHOOTING -
0084 00
Continued
SPECIAL PURPOSE KITS - Continued
Table 1. Special Purpose Kits Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
13. LIGHT MATERIAL
1.
Check to see if
1.
Disconnect NATO cable.
HANDLING CRANE
LMHC control box
(LMHC) DOES NOT
circuit breaker
OPERATE
tripped.
2.
Open cover on LMHC control
3.
If LMHC control box circuit
breaker is tripped, position
LMHC control box circuit
breaker to ON.
4.
Connect NATO cable.
5.
Check LMHC control box
circuit breaker to see if it is
tripped again.
6.
Close cover on LMHC control
box.
2.
Check to see if
1.
If LMHC does not operate,
LMHC operates.
notify Field Maintenance.
0084 00-6