|
|
TM 9-2320-391-10
SPECIAL PURPOSE KITS TROUBLESHOOTING -
0084 00
Continued
SPECIAL PURPOSE KITS - Continued
Table 1. Special Purpose Kits Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
CAB ARCTIC
3.
Shut down cab arctic heater
HEATER TURNS
ITSELF OFF -
Continued
10. CAB ARCTIC
1.
Attempt to start
If cab arctic heater will not
HEATER EMITS
cab arctic heater
start, perform Special
BLACK SMOKE
Purpose Kits Troubleshooting
(WP 0084 00, Malfunction 3,
Cab Arctic Heater Does Not
Start).
2.
Check to see if
1.
If cab arctic heater emits
cab arctic heater
black smoke, notify Field
emits black
Maintenance.
smoke.
2.
Shut down cab arctic heater
11. CAB ARCTIC
1.
Attempt to start
If cab arctic heater will not
HEATER EMITS
cab arctic heater
start, perform Special
WHITE SMOKE
Purpose Kits Troubleshooting
MORE THAN 20
(WP 0084 00, Malfunction 3,
SECONDS AFTER
Cab Arctic Heater Does Not
START-UP
Start).
2.
Check to see if
1.
If cab arctic heater emits
cab arctic heater
white smoke more than 20
emits white
seconds after starting, notify
smoke more than
Field Maintenance.
20 seconds after
starting.
2.
Shut down cab arctic heater
12. CAB ARCTIC
Notify Field Maintenance.
HEATER CANNOT
BE SWITCHED OFF
0084 00-5
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |