ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
122. M1079A1 110 VAC
3. If 110 VAC outlet J234 does
OUTLET J231
not operate, perform step 2
DOES NOT
of this fault. If 110 VAC outlet
OPERATE IN
J233 operates go to step 3 of
NORMAL MODE -
this fault.
Continued
4. Disconnect 110 VAC appliance
from 110 VAC outlet J234.
2. Check circuit
1. Open door on 110/208 VAC
breakers CB7 in
POWER DISTRIBUTION PANEL
110/208 VAC POWER
DISTRIBUTION PANEL
to see if it has
tripped.
2. If circuit breaker CB7 is
tripped, position to ON to
reset.