ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
121. M1079A1 110 VAC
2. Check to see if 110
1. Position BLACKOUT OVERRIDE
OUTLETS J232
VAC outlets J232 and
switch to ON (WP 0031 00).
AND J233 DO NOT
J233 operate in
OPERATE IN
blackout override
BLACKOUT
mode.
OVERRIDE MODE -
Continued
2. Connect any known good 110
VAC appliance to 110 VAC
outlet J232 or J233.
3. Check for 110 VAC appliance
operation.
4. If 110 VAC outlet J232 or
J233 does not operate in
blackout override mode,
notify Field Maintenance.
5. Disconnect 110 VAC appliance
from 110 VAC outlet.
122. M1079A1 110 VAC
1. Check 110 VAC outlet
1. Connect any known good 110
OUTLET J231
J234 for operation.
VAC appliance to 110 VAC
DOES NOT
outlet J234.
OPERATE IN
NORMAL MODE
NOTE
When either door or any blackout shield is open, van will not have AC
power unless BLACKOUT OVERRIDE switches are activated.
During blackout override only two forward AC outlets (J232 and J233) will have power.
2. Check for 110 VAC appliance
operation.
0069 00-117