TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
122. M1079A1 110 VAC
3. Position master power switch
OUTLET J231
to on (WP 0004 00).
DOES NOT
OPERATE IN
NORMAL MODE -
Continued
4. If circuit breaker trips again,
notify Field Maintenance.
5. Position master power switch
to off (WP 0004 00).
6. Close door on 110/208 VAC
POWER DISTRIBUTION
PANEL.
3. Check 110 VAC outlet
1. Connect any known good 110
J231 for operation.
VAC appliance to 110 VAC
outlet J234.
2. Check for 110 VAC appliance
operation.
3. If 110 VAC outlet J231 does
not operate, notify Field
Maintenance.
4. Disconnect 110 VAC appliance
from 110 VAC outlet J231.
123. M1079A1 110 VAC
1. Check 110 VAC outlet
1. Connect any known good 110
OUTLET J230
J235 for operation.
VAC appliance to 110 VAC
DOES NOT
outlet J235.
OPERATE IN
NORMAL MODE
0069 00-119
|