ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
114. ALL M1079A1
2. Check to see if 110
If 110 VAC outlets do not
FLUORESCENT
VAC outlets operate
operate, perform Malfunction
LIGHTS DO NOT
131 (110 VAC Power Does
ILLUMINATE -
Not Operate).
Continued
3. Check to see if
If fluorescent lights do not
fluorescent lights
illuminate, notify Field
illuminate (WP 0031
Maintenance.
115. M1079A1
Check to see if any
1. If no fluorescent light
FLUORESCENT
fluorescent light
illuminates, perform
LIGHT(S) DS80
illuminates (WP 0031
Malfunction 114 (All M1079A1
AND/OR DS81 DO
Fluorescent Lights Do Not
NOT ILLUMINATE
Illuminate).
2. If other fluorescent lights
illuminates, notify Field
Maintenance.
116. M1079A1
Check to see if any
1. If no fluorescent light
FLUORESCENT
fluorescent light
illuminates, perform
LIGHT(S) DS82
illuminate (WP 0031
Malfunction 114 (All M1079A1
AND/OR DS83 DO
Fluorescent Lights Do Not
NOT ILLUMINATE
Illuminate).
2. If other fluorescent lights
illuminate, notify Field
Maintenance.
0069 00-110