TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
117. M1079A1 110 VAC
1. Check 110 VAC outlet
OUTLET J233
J232 for operation.
DOES NOT
OPERATE IN
NORMAL MODE
NOTE
When either door or any blackout shield is open, van will not have AC
power unless BLACKOUT OVERRIDE switches are activated.
During blackout override only two forward AC outlets (J232 and J233) will have power.
1. Connect any known good 110
VAC appliance to 110 VAC
outlet J232.
2. Check for 110 VAC appliance
operation.
3. If 110 VAC outlet J232 does
not operate, perform
Malfunction 120 (M1079A1
110 VAC Outlet J232 Does Not
Operate in Normal Mode).
4. Disconnect 110 VAC appliance
from 110 VAC outlet J232.
2. Check 110 VAC outlet
1. Connect any known good 110
J233 for operation.
VAC appliance to 110 VAC
outlet J233.
2. Check for 110 VAC appliance
operation.
3. If 110 VAC outlet J233 does
not operate, notify Field
Maintenance.
4. Disconnect 110 VAC appliance
from 110 VAC outlet J233.