ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
114. ALL M1079A1
1. Check circuit
1. Open door on 110/208 VAC
FLUORESCENT
breakers CB6 in
POWER DISTRIBUTION PANEL
LIGHTS DO NOT
110/208 VAC POWER
ILLUMINATE
DISTRIBUTION PANEL
to see if it has
tripped.
2. If circuit breaker CB6 is
tripped, position to ON to
reset.
3. Check to see if fluorescent
lights illuminate (WP 0031
4. If circuit breaker trips again,
notify Field Maintenance.
5. Close door on 110/208 VAC
POWER DISTRIBUTION
PANEL.
0069 00-109
|