TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
111. M1079A1 FAN
2. Check to see if
If fluorescent lights do not
DOES NOT
fluorescent lights
illuminate, perform Electrical
OPERATE -
illuminate (WP 0031
System Troubleshooting (WP
Continued
VAC Power Does Not
Operate).
3. Check to see if fan
If fan does not operate, notify
operates (WP 0032
Field Maintenance.
112. ALL M1079A1 VAN
1. Check to see if cab
If cab top clearance and
BODY CLEARANCE
top clearance and
marker lights do not
AND MARKER
marker lights
illuminate perform
LIGHTS DO NOT
illuminate (WP 0016
Malfunction 55 (One Or More
ILLUMINATE
Cab Top Marker Lights Do Not
Illuminate).
2. Check to see if van
If van body clearance and
body clearance and
marker lights do not
marker lights
illuminate notify Field
illuminate (WP 0016
Maintenance.
113. M1079A1 VAN
Check to see if any
1. If no van body clearance and
BODY CLEARANCE
van body clearance
marker lights illuminate,
OR MARKER LIGHT
and marker lights
perform Malfunction 112 (All
DOES NOT
illuminate (WP 0016
M1079A1 Van Body Clearance
ILLUMINATE
and Marker Lights Do Not
Illuminate).
2. If other van body clearance or
marker lights illuminate,
notify Field Maintenance.
0069 00-108
|