ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
111. M1079A1 FAN
1. Check circuit breaker
1. Open door on 110/208 VAC
DOES NOT
CB8 in 110/208 VAC
POWER DISTRIBUTION PANEL
OPERATE
POWER
DISTRIBUTION PANEL
to see if it has
tripped.
2. If circuit breaker CB8 is
tripped, position to ON to
reset.
3. Check to see if fan operates
4. If circuit breaker trips again,
notify Field Maintenance.
5. Close door on 110/208 VAC
POWER DISTRIBUTION PANEL
0069 00-107