TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
110. INLET AIR HEATER
1. Check circuit breaker
1. Remove PDP cover (WP 0095
DOES NOT
CB22 in PCB to see if
OPERATE
it is tripped.
2. If circuit breaker is tripped,
push in to reset.
3. Position master power switch
to on (WP 0004 00).
4. Check circuit breaker to see if
it is tripped. If circuit breaker
is tripped or trips again, notify
Field Maintenance.
5. Position master power switch
to off (WP 0004 00).
6. Install PDP cover (WP 0095
2. Check to see if inlet
If inlet air heater does not
air heater operates
operate, notify Field
Maintenance.
0069 00-106
|