TM 9-2320-386-24-1-1
0017 00
Table 2. STE/ICE-R NO-GO-Chain Tests (Contd)
NOTE
Test G01, VTM Connections and Checkout, must be
performed before running any other STE/ICE-R test.
DCA
GAUGE TEST
NG31
MODE
INSTALL TEST PROBE CABLE:
1
Connect P1 of test probe cable W2 to J4 on VTM.
Touch red and black leads together.
DO TEST PROBE CABLE OFFSET:
2
Dial 89 into TEST SELECT.
PROMPTING
Press and hold TEST until CAL message
MESSAGE
appears on display.
Release TEST.
TEST NO.
TEST
Wait for offset value to appear on display.
89
0-45 VOLTS DC
Is offset value within limits of -6.8 to +6.8?
YES
NO
STE/ICE-R is bad. Replace.
Proceed to step 3.
3
|