HEATING SYSTEMS TROUBLESHOOTING (Contd)
Table 1. Heating Systems Troubleshooting Procedures (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 1. Check horn operation. Place
1. If horn fails to operate, go to
2. HOT WATER
power accessory switch to the
WP 0014 00, table 1,
PERSONNEL HEATER
ON position. Push horn button.
malfunction 10.
DOES NOT OPERATE
OR DOES
2. If horn is operational, voltage is
NOT OPERATE
present at input of heater circuit
IN LOW POSITION
breaker. Go to test 2.
3. If heater high/low switch operates
in high but fails to operate in low,
go to test 5.
Test 2. Check heater high/low switch
for power input.
1. Set multimeter to a range that
will measure 24 VDC.
2. Disconnect lead 10 at rear of
heater switch.
3. Touch multimeter positive lead
to contact end of lead 10 at
heater switch.
4. Touch multimeter negative lead 1. If voltage is present, go to test 3.
to frame ground. Voltage
2. If voltage is not present, repair or
should be present.
replace lead 10 (WP 0090 00).
Test 3. Test for power output at heater
high/low switch.
1. Set multimeter to a range that
will measure 24 VDC.
2. Reconnect lead 10 and
disconnect lead 400 at rear of
heater switch at the high
switch side. Place switch in the
high position.
3. Touch positive lead of multimeter
to contact end of power output
at the heater switch.
4. Touch multimeter negative lead 1. If voltage is present, go to test 4.
to frame ground. Voltage
2. If voltage is not present, replace
should be present.
heater switch (WP 0116 00).
TEST 2
STEPS 3
AND 4
HEATER
TEST 3
SWITCH
LEAD
STEPS 3
400
AND 4
|