HEATING SYSTEMS TROUBLESHOOTING (Contd)
Table 1. Heating Systems Troubleshooting Procedures (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 4. Test personnel heater for
2. HOT WATER
power input.
PERSONNEL HEATER
DOES NOT OPERATE
1 Ensure heater switch is in
OR DOES NOT
high position.
OPERATE IN LOW
2. Set multimeter to a range
POSITION (Contd)
that will measure 24 VDC.
3. Disconnect lead 400 from
personnel heater.
4. Touch multimeter positive
lead to contact end of lead
400.
5. Touch multimeter negative
1. If voltage is not present, repair or
lead to frame ground. Voltage
replace lead 400 (WP 0090 00).
should be present.
2. If voltage is present, and personnel
heater fails to operate, replace
personnel heater (WP 0250 00).
Test 5. Test blower motor resistor.
1. Set multimeter to RX 1.
2. Ensure heater switch is set to
low position.
3. Touch positive lead of
multimeter to one lead on
resistor.
4. Touch negative lead of
If resistance is not within tolerance of
multimeter to the other end
4.5 ohms and 5.5 ohms, replace
of resistor.
resistor (WP 0117 00).
TEST 4
STEPS 4
AND 5
LEAD
400
0015 00-8
|