TM 9-2320-209-34-2-3
FRAME 4
NOTE
Fuel flow test and adjustment should be done even on a
new fuel control valve. Fuel control valve must be
adjusted for use with different fuels. A stop watch or
watch with a second hand is needed for this test.
Hold fuel outlet (1) of fuel control valve (2) over overflow container (3).
1.
2.
Be sure HI-LO switch (4) is in LO position. Flip control switch (5) to RUN
position. Fuel pump should be pumping.
Let fuel flow into overflow container (3) for a
Flip HI-LO switch (4) to HI.
3.
few seconds.
4.
Let fuel flow into graduate (6) for exactly one minute. Flip HI-LO switch (4)
to LO. Flip control switch (5) to OFF position.
Place graduate (6) on a level surface. Read level of fuel (7) as shown. Level
5.
of fuel should be as in table for type of fuel used.
Diesel Fuel
Combat
FUEL TYPE
DFA
DF1
DF2
Gasoline
Flow Rate
14 to 18
15 to 19
14 to 18
15 to 19
(cc/mm)
If fuel flow is not within range of table, get a new fuel control valve (2).