TM 9-2320-209-34-2-3
FRAME 26
1.
Grind off flat end on retaining pin (1).
2.
Drive pin (1) out of collar (2).
3.
Take off collar (2) from stud (3).
NOTE
Do not take out stud (3) from end of worm shaft (4)
unless threads are damaged. Refer to para 18-5e for
inspection procedures.
4.
Take out stud (3) from end of worm shaft (4).
END OF TASK