TOOLS: 3/4-inch wrench
Scraper
SUPPLIES: Delivery pump gasket
Solvent, dry cleaning, type II (SD-2), Fed. Spec P-D-680
Compressed air source, 30 psi max
PERSONNEL: One
EQUIPMENT CONDITION: Truck parked, engine off, handbrake set.
WARNING
Smoking, flame, sparks, and glowing or hot
objects are not allowed within 50 feet of work
area. Fuel may burn, causing explosion, injury
to personnel, and damage to equipment.
a. Removal.
FRAME 1
1.
Using wrench, unscrew and take out four screws (1). Take off four lock-
washers (2).
2.
Take off strainer cover (3) and gasket (4). Throw away gasket.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when
solvent is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
3. Using solvent, clean strainer cover (3). Use scraper, if needed, to get off
all gasket pieces.
GO TO FRAME 2
|