TM 9-2320-209-20-3-3
FRAME 2
1.
Take out strainer (1) from strainer housing (2).
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when solvent
is used. Use only in well-ventilated places. Failure to
do this may result in injury to personnel and damage to
equipment.
2. Using solvent, clean strainer (1). Dry with compressed air. Make sure
there is no dirt left in strainer.
3. Using solvent, clean flange (3). Use scraper, if needed, to get off all
gasket pieces. Do not get any gasket pieces in strainer housing (2).
END OF TASK