TM 9-2320-209-20-3-1
CIRCUIT BREAKER REMOVAL AND REPLACEMENT.
TOOLS:
Cross-tip screwdriver (Phillips type)
SUPPLIES:
None
PERSONNEL:  One
EQUIPMENT
CONDITION:
Truck parked, engine off, handbrake set.
a.
Preliminary Procedures.
(1) Open hood and left side panel. Refer to TM 9-2320-209-10.
(2) Disconnect battery ground cable. Refer to para 7-58.
b.
Removal.
FRAME 1
1.
Take off connectors (1 and 2).
2.
Using phillips screwdriver, unscrew two screws (3). Take out screws and take
circuit breaker (4) off firewall (5).
NOTE
Trucks with auxiliary power outlets have an additional
15-ampere circuit breaker. This circuit breaker is
located next to circuit breaker (4). Removal procedures
are same for both breakers.
END OF TASK