TM 9-2320-209-20-3-1
c. Replacement.
WARNING
Dry cleaning solvent is flammable. Do not use near
an open flame. Keep a fire extinguisher nearby when
solvent is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
Clean surfaces of housing assembly (1) and mounting elbow (2) with solvent.
1.
Put gasket (3) on four threaded studs (4).
2.
Press housing assembly (1) over threaded studs (4) until it is seated
3.
against gasket (3).
Put clamp (5) holding ignition harness (6) on bottom right threaded stud (4).
4.
Using 1/2-inch wrench, screw on and tighten four nuts (7) with four lockwashers (8).
5.
GO TO FRAME 2