b.
Aline screw holes in air cleaner indicator (1) with screw holes in bracket (2)
1.
and put in two cap screws (3) .
2.
Using 7/16-inch wrenches, hold two capscrews (3) and screw on and tighten
two washers (4) and nuts (5) .
Working from behind instrument panel and using 7/16-inch wrench, screw in
3.
connector fitting (6) .  Hold connector fitting and using 9/16-inch wrench,
screw in and tighten fitting (7) .
END OF TASK