Page Title: AIR CLEANER INDICATOR REMOVAL AND REPLACEMENT.
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-209-20-3-1
4-4. AIR CLEANER INDICATOR REMOVAL AND REPLACEMENT.
TOOLS :  7/16-inch open end wrench
9/16-inch wrench (2)
None
SUPPLIES :
One
PERSONNEL:
Truck parked, engine off, handbrake set.
EQUIPMENT
CONDITION:
.
Removal.
Working from behind instrument panel and using 7/16-inch wrench, hold
1.
connector fitting (l).  Using 9/16-inch wrench, unscrew fitting (2) and
take off tube assembly ( 3).  Unscrew and take off connector fitting.
2.
Using 7/16-inch wrenches, unscrew and take off two capscrews ( 4),
washers (5), and nuts (6) and take off air cleaner indicator ( 7).
END OF TASK
TA
080844