TM 9-6115-663-13&P
3. Refer to power plant wiring diagram (figure FO-1) for identification of components inside switch box
assembly and check:
a. Refer to table 5-1 and check continuity of wiring harness W20 (7).
From
To
Wire Number
1
XDS1-1
P3-A
2
XDS1-2
P3-B
XDS3-2
P3-C
3
4
P3-D
S1-3
P3-F
5
S1-5
P3-G
6
S1-6
P3-H
7
S2-6
8
P3-I
S2-5
P3-K
9
S2-3
10
XDS4-2
P3-L
11
XDS2-1
P3-M
XDS2-2
P3-N
12
13
S1-3
XDS3-1
XDS4-1
S2-3
14
b. Remove electrical connector cover, refer to table 5-2 and check continuity of wiring harness W9 (18).
NOTE
The bus bar is physically connected to LO of the switch box assembly and is a common
ground. Wires connected to bus bar maybe connected to any terminal on the bus bar.
|