TM 9-6115-663-13&P
NOTE
This PMCS table lists the checks and services as performed on a single Power
Unit. These procedures must be duplicated on each Power Unit that makes
up the AN/MJQ-41.
Unit B of the ANMJQ-41, PU-805, and PU-806 does not have a switch box.
Maintenance for the switch box is only applicable to Unit A of the
AN/MJQ-41.
Not Fully Mission
Item to be
Item
Procedure
Capable if:
Interval
Checked or Serviced
No.
WARNING
Before performing any maintenance that requires climbing on or under trailer, make
sure that trailer handbrakes are set, trailer front landing leg is lowered, and rear
leveling-support jack is lowered. Injury to personnel could result from trailer suddenly
rolling or tipping.
Power cable is
Inspect power cable for worn,
POWER CABLE
Semi-
1
frayed or cracked insulation,
unserviceable.
annually
(AN/MJQ-41 only)
loose terminal lugs, and loose
connections. Tighten as needed.
a. Inspect switch box assembly.
SWITCH BOX ASSEMBLY
2
Semi-
Refer to paragraph 4-12.
annually
(AN/MJQ-41 only)
b. Inspect mounting brackets for
cracks or loose or missing
hardware.
Inspect for cracks and
Mounting rail is
MOUNTING RAILS
3
Semi-
deformation.
cracked or deformed.
annually
a. Inspect for broken seal and
4
FIRE EXTINGUISHER
Semi-
damage to handle.
annually
Fire extinguisher not
b. Weigh to determine whether
charge is sufficient. Weight is charged.
about 13 pounds when filly
charged. If weight is 12.5
pounds or less, send to
specialized activity for
recharging.
|