Table 2-2. Operator Preventive Maintenance Checks and Services
for AN/MJQ-41, PU-805, and PU-806 (continued)
Location
Item
Not Fully Mission
Interval
No.
Item to Check/Service
Procedure
Capable if:
SET -
continued
Before
29
CONTROLS AND
a. Check indicators and controls
Indicators or controls
INDICATORS
for damage or missing parts.
damaged or missing.
b.Place PRIME RUN switch to
AUX PRIME RUN and press
TEST RESET LAMPS button
on fault indicator. All test
lamps must light.
c .Check fuel gauge for fuel
indication.
Before
30
CONTROL BOX HARNESS
Check inside control box for loose
Loose or damaged
or damaged  wiring.
wires.
2-22