TM 9-6115-661-13&P
Table 2-2. Operator Preventive Maintenance Checks and Services (continued)
1
Location
Not Fully Mission
Item
Capable if:
Procedure
I n t e r v a l Item to Check/Service
No.
Exercise extreme caution when performing DURING checks inside engine
compartment. Avoid contact with moving or hot engine parts. Failure to observe
this-warning can result in severe personal injury or death.
GENERATOR SET
Check for loose, damaged or
During
ENGINE ASSEMBLY
37
missing parts.
Any fuel leaks.
Inspect for leaks.
During
FUEL SYSTEM
38
Class III leaks.
a. Inspect for leaks.
During
LUBRICATION SYSTEM
39
b. Check oil level on dipstick, both Oil level below ADD
level.
sides,
Listen for unusual noise in fan
40
During
COOLING FAN
area.
Cable is missing or
GROUND ROD CABLE AND Inspect ground rod and cable for
During
41
loose connections, breaks, damage, damaged.
CONNECTIONS
I and corrosion.
I
High voltage is produced when this generator set is operating. Improper operation
could result in injury or death,
Observe the following Indicators
During
CONTROLS AND
42
and ensure they are functioning.
INDICATORS
Coolant temp, 170-200F (77-
93 c)
Oil pressure, 25-60 psi (172-
414kPA)
Change 3
2-26
|