Table 2-2. Operator Preventive Maintenance Checks and Services (continued)
Location
Not Fully Mission
Item
Capable if:
Procedure
Item to Check/Service
Interval
No.
WARNING
Battery acid can cause burns to unprotected skin.
Batteries give off a flammable gas. DO NOT smoke or use open flame when
performing maintenance on batteries. Flames and explosion could result in severe
personal injury or death.
GENERATOR SET -
continued
Batteries not
a. Check batteries for damage or
Before
BATTERIES
26
charged.
missing caps.
b. Inspect electrolyte level. If low
notify next higher maintenance
level.
Cables are damaged
Inspect cables and connectors for
BATTERY CABLES
Before
27
or missing.
corrosion, damage, loose, or
missing parts.
WARNING
DO NOT touch live voltage connections. High voltage is produced when this generator
set is operating. Personal injury or death due to electrocution could result.
Before
Missing or damaged
28
OUTPUT BOX ASSEMBLY
a. Check for loose or damaged
wiring or cables.
wiring or cables.
Damaged or missing
b. Check output terminals for
hardware.
damage or missing hardware.