TM 9-6115-661-13&P
Table 2-2. Operator Preventive Maintenance Checks and Services (continued) .
Location
Not Fully Mission
Item
Capable if:
Procedure
Item to Check/Service
Interval
No.
GENERATOR SET
Ensure that acoustical materials,
ACOUSTICAL MATERIALS
14
Before
located in the grill areas, are
secure, not damaged or missing.
WARNING
With any access door open, the noise level of this generator set could cause hearing
damage. Hearing protection must be worn when working near the generator set
while working.
WARNING
The fuels used in this generator set are highly explosive. DO NOT smoke or use
open flame when performing maintenance. Flames and explosion can occur,
resulting in severe personal injury or death.
Any fuel leaks. Any
Before
Visually inspect the generator
15
ENGINE ASSEMBLY
Class III oil or
set for fuel, oil and coolant
coolant leaks.
leaks. Check for proper ground
connections.
Any condition that
Visually inspect the engine for
enders power
missing, loose, or damaged
unit/power plant not
parts and hardware, and for
mission capable.
unusual wear or deterioration.
DEAD CRANK switch to
NORMAL.
2-18
Change 3
|