TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
141. 24 VOLTS GAGE
4. If OIL PRESS gage does not
DOES NOT
operate, perform Malfunction
OPERATE OR IS
143 (24 VOLTS Gage, OIL
INACCURATE
PRESS Gage, WATER TEMP
(VEHICLE S/N
Gage, and Speedometer Do
100,001 TO
Not Operate).
199,999) -
Continued
5. If OIL PRESS gage operates,
notify Field Maintenance.
142. 12 VOLTS GAGE
1. Does any other
1. Position master power switch
DOES NOT
electrical gage
to on (WP 0004 00).
OPERATE OR IS
operate?
INACCURATE
(VEHICLE S/N
100,001 TO
199,999)
2. Check to see if any other
electrical gages operate.
3. Position master power switch
to off (WP 0004 00).
4. If no other electrical gage
operates, perform
Malfunction 134 (All Electrical
Gages Do Not Operate).
5. If other electrical gages
operate, notify Field
Maintenance.
143. 24 VOLTS GAGE,
Notify Field Maintenance.
OIL PRESS GAGE,
WATER TEMP
GAGE, AND
SPEEDOMETER DO
NOT OPERATE
(VEHICLE S/N
100,001 TO
199,999)
0069 00-144
|