TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
140. REMOTE START
1. Check to see if
1. Position master power switch
DOES NOT
engine starts using
to on (WP 0004 00).
OPERATE
instrument panel
2. Attempt to start engine (WP
(VEHICLE S/N
controls.
18,550 OR
HIGHER)
3. If engine starts, check to see
if any instrument panel gages
operate. If engine starts and
any gages operate, Notify
Field Maintenance.
4. Position master power switch
to off (WP 0004 00).
141. 24 VOLTS GAGE
1. Does any other
1. Position master power switch
DOES NOT
electrical gage
to on (WP 0004 00).
OPERATE OR IS
operate?
INACCURATE
2. Check to see if any other
(VEHICLE S/N
electrical gages operate.
100,001 TO
199,999)
3. Position master power switch
to off (WP 0004 00).
4. If no other electrical gage
operates, perform
Malfunction 134 (All Electrical
Gages Do Not Operate).
5. If other electrical gages
operate, go to test 2 of this
malfunction.
2. Does OIL PRESS
1. Start engine (WP 0016 00).
gage operate?
2. Check to see if OIL PRESS
gage operates.
3. Shut down engine (WP 0016
0069 00-143
|