TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
129. M1079A1 24 VDC
1. Check to see if circuit
1. If circuit breaker is tripped,
BINDING POST(s)
breaker CB11 is
push in to reset and perform
DOES NOT
tripped.
test 2 of this malfunction.
OPERATE
2. If circuit breaker CB11 is not
tripped, perform test 2 of this
malfunction.
2. Check to see if 24
If 24 VDC binding post do not
VDC binding post
operate, notify Field
operates (WP 0033
Maintenance.
130. VAN DOOR
1. Check to see if LAMP
1. If LAMP TEST switch does not
INDICATOR DOES
TEST switch
illuminate VAN DOOR
NOT ILLUMINATE
illuminates VAN
indicator, go to test 2 of this
DOOR indicator (WP
malfunction.
2. If LAMP TEST switch
illuminates VAN DOOR
indicator, notify Field
Maintenance.
0069 00-127
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |