TM 9-2320-391-10
ELECTRICAL SYSTEM TROUBLESHOOTING - Continued 0069 00
ELECTRICAL SYSTEM Continued
Table 5. Electrical System Troubleshooting Procedures Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
120. M1079A1 110 VAC
1. Check to see if
If fluorescent lights do not
OUTLET J232
fluorescent lights
operate, perform Malfunction
DOES NOT
illuminate (WP 0031
131 (110 VAC Power Does
OPERATE IN
Not Operate).
NORMAL MODE
2. Check 110 VAC outlet
1. Connect any known good 110
J233 for operation.
VAC appliance to 110 VAC
outlet J233.
NOTE
When either door or any blackout shield is open, van will not have AC
power unless BLACKOUT OVERRIDE switches are activated.
During blackout override only two forward AC outlets (J232 and J233) will have power.
2. Check for 110 VAC appliance
operation.
3. If 110 VAC outlet J233 does
not operate, perform step 3
of this fault. If 110 VAC outlet
J233 operates go to step 4 of
this fault.
4. Disconnect 110 VAC appliance
from 110 VAC outlet J233.
0069 00-114
|