ELECTRICAL WIRING HARNESS REPAIR (Contd)
CONNECTOR CABLE REPAIR
1. Strip cable insulation (12) to depth of solder wells (4) on inserts (15).
2. Slide cable ends (18) through retaining nut (13) and grommet (14).
NOTE
Refer to TM 9-237 for soldering instructions.
3. Position cable ends (18) into solder wells (4) and solder.
NOTE
Inserts may be either male or female. Coupling nuts will have a
matching configuration.
4. Slide grommet (14) over inserts (15) and press grommet (14) into coupling nut (17) until seated.
5. Install grommet retaining nut (13) on threads (16) of coupling nut (17) and tighten until seated.
6. Connect battery ground cable (WP 0121 00).