Page Title: FUEL SHUTOFF SOLENOID REPLACEMENT - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-386-24-1-1
0050 00
FUEL SHUTOFF SOLENOID REPLACEMENT (Contd)
5.
Move coolant hose (2) back to its original position and tighten nut (4) on elbow (5).
6.
Apply sealant to threads of elbow (14) and install elbow (14) back in its original position on air
7.
Install tube (16) on elbow (14) and tighten nut (15).
8.
Install oil filler tube (WP 0031 00).
9.
Connect battery ground cable (WP 0121 00).
5
4
3
2
1
~
15
16
~
14
6
13
7
12
11
10
9
8
6
7
END OF WORK PACKAGE