Click here to make tpub.com your Home Page

Page Title: FUEL SHUTOFF SOLENOID REPLACEMENT - continued
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-386-24-1-1
0050 00
FUEL SHUTOFF SOLENOID REPLACEMENT (Contd)
.WARNING.
Diesel fuel is flammable. Do not perform fuel system procedures near
open flame, sparks, or electricity. Injury to personnel may result.
Do not disconnect air lines or hoses before draining air reservoirs. Small
parts under pressure may shoot out at high velocity causing injury to
personnel.
Eyeshields must be worn when releasing compressed air. Failure to do so
may cause injury to personnel.
REMOVAL
1.  Loosen nut (15) and remove tube (16) from elbow (14).
NOTE
Note position of elbow for installation.
Note position of coolant hose for installation.
2.  Remove elbow (14) from air compressor (1).
3.  Loosen nut (4) one-half turn on elbow (5) and move coolant hose (2) out of the way to access fuel
shutoff solenoid (11).
CAUTION
When disconnecting air lines and hoses, plug all openings to prevent
dirt from entering and causing damage to internal parts. Remove all
plugs prior to installation.
4.
Remove two nuts (7), lockwashers (6), and ground (GND) lead (8) from one terminal and leads 54A (10)
and 770-R (9) from other terminal on fuel shutoff solenoid (11). Discard lockwashers (6).
5.
Using spanner wrench, remove fuel shutoff solenoid (11) and O-ring (13) from fuel pump (3).
Discard O-ring (13).
INSTALLATION
.WARNING.
Skysol-100 mixture is combustible. Use mechanical ventilation whenever
product is used in a confined space, is heated above ambient
temperatures, or is agitated. DO NOT use or store near heat, sparks,
flame, or other ignition sources. Keep container sealed when not in use.
Contact with Skysol-100 may cause skin irritation. Use chemical resistant
gloves. In case of skin contact, remove any contaminated clothing and
wash skin thoroughly with soap and water. Wash contaminated clothing
before reuse. Eye contact may cause irritation, tearing, or blurring of
vision. Use face shield or goggles when eye contact may occur. In case of
eye contact, flush eyes with large amounts of water for at least fifteen (15)
minutes or until irritation subsides. Inhalation may cause irritation to
upper respiratory passages. DO NOT have food or drink in the vicinity.
1.
Clean fuel shutoff solenoid sealing area (12) with Skysol-100.
2.
Install new O-ring (13) on fuel shutoff solenoid (11).
3.
Using spanner wrench, install fuel shutoff solenoid (11) on fuel pump (3).
4.
Install ground (GND) lead (8) on one terminal and leads 54A (10) and 770-R (9) on other terminal
of fuel shutoff solenoid (11) with two new lockwashers (6) and nuts (7).
0050 00-2

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business