0010 00
Unit Mechanical Troubleshooting (Contd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
PERSONNEL FUEL BURNING HEATER/POWER PLANT HEATER KIT
54. HEATER WILL NOT OPERATE IN HIGH OR LOW POSITION
Refer to Electrical Troubleshooting, WP 0011 00.
55. HEATER WILL NOT OPERATE
WARNING
Diesel fuel is flammable. Do not perform fuel system procedures
near open flame. Injury or death to personnel may result.
Compressed air source will not exceed 30 psi (207 kPa). When
cleaning with compressed air, eyeshields must be worn. Failure to
wear eyeshields may result in injury to personnel.
Step 1. Refer to Electrical Troubleshooting, WP 0011 00.
Step 2. Check fuel shutoff valve and ensure it is in full ON position.
If fuel shutoff valve is damaged (or stuck in OFF or partial ON position), replace fuel
shutoff valve (TM 9-2320-361-20).
Step 3. Check heater fuel filter for contamination.
If water or contamination is present, clean and flush entire fuel system. Dry with
compressed air (TM 9-2320-386-10).
Step 4. Check fuel lines for breaks, bends, kinks, or leaking joints.
If broken, kinked, or if leaky joints are found, refer to TM 9-243.
Step 5. Check fuel pump discharge.
a. Remove fuel line from fuel pump output.
b. Use clean container for fuel discharge recovery.
c. Position heater control box to RUN position.
d. If fuel pump fails to pump adequate amount of fuel, 1/2 pint (0.24 L) in 30 seconds,
replace fuel pump (WP 0249 00).
Step 6. Inspect exhaust system for restrictions.
If exhaust pipe is restricted or damaged, repair or replace exhaust pipe (WP 0251 00).
Step 7. If fuel burning heater still fails to operate, replace fuel burning heater (WP 0247 00).
Step 8. Check for proper operation of defroster and heat diverter control cables (TM 9-2320-386-10).
If control cables or vent are broken, replace (WP 0242 00).
END OF TESTING!
END OF WORK PACKAGE