TM 9-2320-361-24-2
FIELD MAINTENANCE INSTRUCTIONS
FOR SPECIAL PURPOSE KITS
2-1/2 TON, 6X6, M44A2 SERIES TRUCKS (MULTIFUEL)
FUEL BURNING PERSONNEL HEATER TESTING
PREPARATION, FLAME DETECTOR SWITCH TEST, FUEL CONTROL VALVE TEST, FLAME DETECTOR SWITCH TEST,
OVERHEAT SWITCH TEST, AND TEST EQUIPMENT REMOVAL
INITIAL SETUP:
Applicable Models
References
All
Tools and Special Tools
Equipment Condition
General mechanic's tool kit
Parking brake set and wheels chocked
(item 116, WP 0469 00)
(TM 9-2320-361-10).
Multimeter (item 51, WP 0469 00)
Battery ground cable disconnected
Flowmeter
(WP 0126 00).
Test stand
Fuel burning personnel heater removed
Materials/Parts
Two nut-assembled lockwashers
(item 247, WP 0470 00)
0435 00-1