TM 9-2320-361-24-2
0427 00
PERSONNEL HEATER GUARD AND BLOWER MOTOR REPLACEMENT (Contd)
GUARD REMOVAL
Release two fasteners (10) and remove guard (1) from heater housing (7).
BLOWER MOTOR REMOVAL
NOTE
Prior to removal, tag lead wires for installation.
1.
Remove screw-assembled lockwasher (2) and blower motor lead (3) from flame detector switch (4).
Discard screw-assembled lockwasher (2).
2.
Remove screw (5) and nut-assembled lockwasher (9) from clamp (6) and ignition control unit (8).
Discard nut assembled lockwasher (9).
3.
Remove grommet (11) from heater housing (7).
4.
Loosen four screw-assembled lockwashers (12) and remove blower motor (13) from heater
housing (7). Discard screw-assembled lockwashers (12).
BLOWER MOTOR INSTALLATION
1.
Install grommet (11) in heater housing (7).
2.
Route blower motor lead (3) through grommet (11) in heater housing (7).
3.
Install blower motor (13) on heater housing (7) by tightening four new screw-assembled
lockwashers (12).
4.
Install blower motor lead (3) on flame detector switch (4) with new screw-assembled
lockwasher (2).
5.
Install clamp (6) on ignition control unit (8) with screw (5) and new nut-assembled lockwasher (9).
GUARD INSTALLATION
1.
Position guard (1) on heater housing (7) and hold in place with two fasteners (10).
2.
Install fuel burning personnel heater (WP 0351 00).
3.
Connect battery ground cable (WP 0126 00).
4.
Test fuel burning personnel heater (WP 0435 00).
5.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).
0427 00-2
|